Loading...
HomeMy WebLinkAbout14.a. Receive 2021 National Pollutant Discharge Elimination System (NPDES) Annual Report Page 1 of 5 Item 14.a. CENTRALSAN jdf A- hom CENTRAL CONTRA COSTA SANITARY DISTRICT March 3, 2022 TO: HONORABLE BOARD OF DIRECTORS FROM: ALAN WEER, PLANT OPERATIONS DIVISION MANAGER REVIEWED BY: STEVE MCDONALD, DIRECTOR OF OPERATIONS ROGER S. BAILEY, GENERAL MANAGER SUBJECT: RECEIVE THE 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)ANNUAL REPORT The 2021 National Pollutant Discharge Elimination System (NPDES)Annual Report was submitted to the California Regional Water Quality Control Board, San Francisco Bay Section, on January 30, 2022. Plant Operations Division Manager Alan Weer will present the highlights from the annual report. Strategic Plan re-In GOAL ONE: Customer and Community Strategy 2—Maintain a positive reputation GOAL TWO: Environmental Stewardship Strategy 1—Achieve 100% compliance in all regulations ATTACHMENTS: 1. Presentation March 3, 2022 Regular Board Meeting Agenda Packet- Page 99 of 165 Page 2 of 5 + 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM 1� ANNUAL REPORT .1 . I Board of Directors Meeting March 3, 2022 -- Alan Weer Plant Operations Division Manager A. 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ANNUAL REPORT Total Influent Flow Treated = 12.6 billion gallons (12.1 in 2020) Average Daily Effluent Flow= 33.1 million gallons (33.1 in 2020) Average Daily Influent Flow= 34.6 million gallons (35.3 in 2020) Peak Hourly Flow= 174 million gallons per day on October 24, 2021 (78.6 in 2020) Average Dry Weather Flow =29.5 million gallons per day (33.2 in 2020) Ash Disposal = 3627 tons (wet weight for soil amendment), 3451 tons in 2020 _ ' z March 3, 2022 Regular Board Meeting Agenda Packet- Page 100 of 165 1 Page 3 of 5 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ANNUAL REPORT Average Dry Weather Flow and Annual Average Influent Flow 50 45 40 35 30 25 20 15 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 —Average Dry Weather Flow (MGD) —Annual Average Influent Flow(MGD) ADW F(average dry weather flow):the average daily influent flow from the three lowest influent flow months. 'jaI 3 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ANNUAL REPORT CBOD—Carbonaceous Biochemical Oxygen Demand A measure of oxygen used by microorganisms Entero— Enterococci A measure of bacteria TSS—Total Suspended Solids A measure of suspended particles Bioassay A measure for evaluating the potential harmful effects of effluents discharged into surface waters 4 1' March 3, 2022 Regular Board Meeting Agenda Packet- Page 101 of 165 2 Page 4 of 5 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ANNUAL REPORT CBODmonthly average(mg/L)= 8.3 mg/L(Limit= 25 mg/L) CBOD (% removal)= 95.9% (Limit= Minimum of 85%) TSSmonthly average(mg/L)= 9.4 mg/L(Limit= 30 mg/L) TSS (% removal)= 96.0% (Limit= Minimum of 85%) Entero Monthly Avg. (MPN/100ml) =4 (Limit Geometric Mean of< 35) Bioassay (11 Sample Median, % survival)= 100% (Limit= > 90%) 2021 NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ANNUAL REPORT • 100 percent compliance with National Pollutant Discharge Elimination System Permit requirements • NACWA Platinum Award — 24th Consecutive Year Peak erformanceor��MlftN�o)-vAWARDS Water Boards -Z March 3, 2022 Regular Board Meeting Agenda Packet- Page 102 of 165 3 Page 5 of 5 ACKNOWLEDGEMENTS Environmental Laboratory Operations Department Engineering Department Administration Department Board of Directors 00gw = 1. RECOMMENDATION Receive the 2021 National Pollutant Discharge Elimination System Annual Report w March 3, 2022 Regular Board Meeting Agenda Packet- Page 103 of 165 4