Loading...
HomeMy WebLinkAbout05. (Handout) Projects Completed/Closed in FY 2013-14Projects Completed /Closed out in FY 2013 -14 Engineering and Operations Committee Meeting August 25, 2014 Closed /Completed Projects during FY13 -14 by Program Program Total Expenditures Treatment Plant $7,466,593 General Improvements $967,016 Recycled Water N/A Collection S,, s� $8,769,301 Total $179202,910 1 s Treatment Plant Program $1 million Project Title Total Expenditures Wet Weather Bypass $ 3,297,882 Improvements $ 960,725 Piping Renovations Phase 7 $ 1,415,110 Treatment Plant Program < $1 million Project Title Expenditures Treatment Plant Facilities Renovations $ 220,016 Treatment Plant Asset Management $ 960,725 Fire Protection Systems Improvements $ 311,157 Treatment Plant Master Plan Update $ 390,922 Secondary Process Improvements $ 47,403 Aux. Boiler Burner Upgrade $187,700 SCB Seismic Upgrade Study $ 137,690 Solids Handling Equipment Evaluation $ 54,115 Aeration System Renovation $ 443,873 PA 0 General Improvements Program < $1 million Project Title Expenditures Imhoff Triangle Development $ 58,321 Martinez Easement Acquisition $ 115,052 Vehicle &Equipment Acquisition FY 2012 -2013 $ 793,643 Back Wet Weather Bypass Improvements Project Purpose: This project improved the treatment plant's wet weather bypass system by constructing a new outlet, under appropriate conditions, ,stored flows can be discharged directly to the Walnut Creek channel. Construction was done in two phases (preioading fill to the clay soils and facilities construction. Scope of Work: • Widened the Bypass Channel &installed box culvert • Constructed a gated bypass structure on the Lower Walnut Creek levee along Basin B. • Grading and Asphalt Paving t Wet Weather Bypass Improvements Project Purpose: This project improved the treatment plant's wet weather bypass system by constructing a new outlet, under appropriate conditions, ,stored flows can be discharged directly to the Walnut Creek channel. Construction was done in two phases (preioading fill to the clay soils and facilities construction. Scope of Work: • Widened the Bypass Channel &installed box culvert • Constructed a gated bypass structure on the Lower Walnut Creek levee along Basin B. • Grading and Asphalt Paving t f I IM767-toW • Engr, CM, Admin (39.5 %) $ 884,189 • Re„ ug latory Efforts $ 175,000 • Total Expenditures $3,297,882 9 5 Piping Renovations, Phase 7 Project Purpose: To improve the reliability of the piping systems above and below ground in the treatment plant by inspection, renovation, and replacement as required. Scope of Work: • RAS piping and valve replacement at Clarifiers. • Centrate piping replacement at Solids Building. • Ash Dust collector replacement and upgrades. • Recycled water replacement gates at Forebay • Ventilation and odor control improvements for sludge loading facility. • Furnace instrumentation improvements. 2 Construction Contract 1t (DW Nicholson) • Change Orders (13.5 %) $ 99,387 • Final Contract $ 835,187 • Engr, CM, Admin (41.4 %) $ 346,346 • DAFT Emergency Costs $ 233,577 • Total Expenditures $1,415,110 7 Pl. Collection System Program > $1 million Project Title Project Title Total Expenditures Total Expenditures North Orinda Renovations, Ph 4 North Orinda Renovations, Ph 4 $2,586,285 $2,586,285 Walnut Creek Renovations, Ph 9 Walnut Creek Renovations, Ph 9 $3,097,032 $3,097,032 N Inspection, Ph 2 TV Inspection, Ph 2 $1,870,714 $1,870,714 Collection System_ Program < $1 million Project Title Total Expenditures Smith Road CAD $124,539 Alhambra Valley Assessment Districts $130,063 Suspended Pipe Support $387,782 San Ramon Bypass Pump $44,391 San Ramon Pumping Station Upgrades $424,331 Martinez Bypass Pump $91,684 Pump Station SCADA O &M Manuals $12,480 CI North Orinda Renovations, Phase 4 Project Purpose: Replace /Renovate deteriorating and high maintenance sewer lines Scope of Work: Reconstruct approximately 14,700 linear feet of 8- to 15 -inch sewers in Orinda 10 Financial Summary Construction Contract $ 1,562,091 (Pacific Trenchless, Inc.) Change Orders • Project related (6.5 %) $101,715 • Added work (6.8 %) $106,446 Total Construction $1,770,252 Right -of -Way (1.7 %) $ 30,580 Survey (8.2 %) $145,747 Engr, CM, Admin (36.1 %) $639,706 Total Expenditures $2,586,285 North Orinda Renovations, Phase 4 Location Map 11 12 Walnut Creek Renovation, Phase 9 Project Purpose: Replace /Renovate deteriorating and high maintenance sewer Fines. Scope of Work: Reconstruct approximately 10,700 linear feet of 6 -,8 -, and10 -inch sewer in Contra Costa County and the City of Walnut Creek. 13 Financial Summary Construction Contract $1,788,794 (Ranger Pipelines, Inc.) Change Orders -Project related (2.6 %) $ 47,201 *Added work (1.5 %) $ 27,038 Total Construction Contract $1,863,033 Right -of -Way (4.3 %) $ 134,700 Survey (6.7 %) $ 208,382 Enqr, CM, Admin (29 %) $ 890,917 Total Expenditures $3,097,032 14 r € tb Sao i v Walnut Creek t ,WALNW CREEX Renovations, Phase 9 �t Location Map r t 14 15 TV Inspection, Phase 2 Project Purpose: Inspect and assess condition of 750,000 feet of sewer lines throughout the District. Results are used to develop CS Renovation Program and optimize CSO's cleaning efforts. Scope of Work: Inspected 737,400 feet of sewer lines. Identified sewers in urgent needs of cleaning and /or repairs. 16 Financial Summary Construction Contract $1,544,000 (Roto Rooter Plumbing Services) Engr, CM, Admin (21.1%) $ 326,714 Total Expenditures $1,870,714 Questions? Back 17