HomeMy WebLinkAboutCAPITAL PROJECTS ACTION SUMMARY 02-14-13Central Contra Costa Sanitary District
(th and the environment 5019 Imhoff
SPECIAL MEETING OF THE B0_41r)OFU1rff cTOxs:
CENTRAL CONTRA COSTA JAXIESA.NEJEDLF
President
SANITARY DISTRICT
DA b7D R. WILLIAd IS
CAPITAL PROJECTS COMMITTEE PresidentPi-oTem
PA UL H. CA USE
111CHAEL R.11CGILL
ACTION SUMMARY TAD J PILECKI
PHOAE: (925) 228 -9500
Chair Pilecki F<Li: (925) 676 -7211
Member Causey (Alternate) www.centralsan.org
Thursday, February 14, 2013
3:00 p.m.
Multi- Purpose Room
5019 Imhoff Place
Martinez, California
PRESENT: Tad Pilecki, Paul Causey (Alternate), Curt Swanson, Dana Lawson, Sasha
Mestetsky, Don Rhoads, Andrew Antkowiak, Thea Vassallo, Doug Craig, Danea
Gemmell, Thomas Brightbill
1. Call Meeting to Order
Chair Pilecki called the meeting to order at 3:00 p.m.
2. Public Comments
None.
3. Discuss the District's current and future approach to Asset Management:
• Treatment Plant
• Collection System
• Pumping Stations /force mains
• Buildings such as the Headquarters Office Building (HOB), Collection System
Operations (CSO), Plant Operations Department (POD) Admin, etc.
• Vehicles
Senior Engineer Dana Lawson presented overview of Treatment Plant Asset
Management Plan (attached). Senior Engineer Sasha Mestetsky presented an
overview of Collection System Asset Management Plan and addressed project
Capital Projects Committee
February 14, 2013
Page 2
selection process for Pumping Stations and Force Mains (attached). Capital
Projects Division Manager Andrew Antkowiak presented an overview of the
proposed seismic and other Improvements to District buildings such as the
Headquarters Office Building (HOB), Collection System Operations (CSO), and
Plant Operations Department (POD) Admin Building (attached). Field Operations
Supervisor Don Rhoads presented an overview of the Fleet Asset Management
Plan (attached).
COMMITTEE ACTION: Received the reports. Discussed various financing
options such as "pay as you go," bond financing, and repayment of
unfunded liabilities. Suggested evaluating the possibility of delaying some
discretionary projects and accelerating repayment of unfunded liabilities.
Recommended re- evaluation of 20 -year event criteria for capacity projects.
4. Discuss how projects are prioritized and what the driving forces are behind the
projects planned for Fiscal Years 2013 -14 and 2014 -15
Capital Projects Division Manager Andrew Antkowiak presented an overview of
prioritization process of 2013 -14 and 2014 -15 Capital Improvement Program.
COMMITTEE ACTION: Received the report. Discussed which projects
could potentially be deferred. Recommended performing pipe condition
degradation analysis based on the results of the first and second phases of
the District -Wide TV Inspection Project.
5. Discuss whether staff should brief members of the Capital Projects Committee
individually before the Capital Improvement Plan /Budget Workshop on April 11,
2013
COMMITTEE ACTION: Discussed and directed staff to schedule another
Committee Meeting after the beginning of March.
6. Reports and Announcements
Finance Manager Thea Vassallo gave an update that the 10 Year Baseline
scenario was rerun to account for the $3 million anticipated lower spending
in capital expenditures for 12113, and a lower annual required contribution
(ARC) for the GASB 45 Trust for 13114 and 14115. In addition, a scenario
was further run to incorporate an immediate $5 million funding of the
Unfunded Actuarial Accrued Liability (UAAL) for both 13114 and 14115. The
original pay down of the UAAL was to be in 15116. The immediate pay down
of the UAAL is doable within the $34 original staff recommendation given
the above - mentioned updates.
Capital Projects Committee
February 14, 2013
Page 3
7. Suggestions for future agenda items
The Committee suggested evaluating the viability of creating an Asset
Management Team and the potential to streamline the CIB /CIP process and
documents, including a two year or more CIB.
8. Adjournment — at 5:40 p.m.
Treatment Plant
Asset Management
Capital Projects Committee Meeting
February 14, 2013
Dana Lawson, PE ^
Senior Engineer, Plant Operations Department
Overview
1. What is asset management?
2. Current state of assets
3. Target level of service
4. Determine risk
5. Optimize Capital and O &M strategies
6. Long Term Funding
7. Future Direction of TP Asset
Management
1
What is Asset Management?
To manage the lifecycle -cost of owning, operating, and
maintaining assets while continuing to meet the District's
mission through the treatment and disposal of
wastewater.
The objective is to provide information to Management & the
Board for rate - setting and budgeting each fiscal year.
ervic Low
RISK
What is Asset Management?
Process:
wERF's 10-Steps of Asset Management from SIMPLE
2
Current State of Assets
Good inventory of TP assets
- Rough estimate for piping needs to be
improved
- Need install dates, condition assessments
-All data stored in Mainsaver®, approx 3000
assets
3
Piping
Inventory
Reinvest $1yr"J
Values I
Total LF
Piping System
$
55,134
$
2,756,704
12,512
AIR
Table 1. Piping Summary by
$
61,976
$
929,636
11,504
CHEMICAL
System
$
1,296
$
64,802
1,080
COMM
$
798,032
$
75,982,899
57,316
DRAIN
ASSUn1Dtlow
$
730,859
(1) Service life assumed to be
$
71,440,440
36,396
EFFLUENT
100 years for large diameter RCP.
$
189,615
$
9,480,765
80,922
ELECTRICAL
75 years for all other gravity pipes,
$
43,129
$
2,156,457
13,579
GAS
50 years for pressure pipes, and
$
53,152
$
2,657,591
10,285
INST
15 years for severe service pipes
$
23,364
$
1,168,200
590
MIXED LIQUOR
(ash, Sludge, scum, etc.).
$
7,138
$
356,898
4,182
OIL
(2) Assumed $30 per inch of
$
695
$
34,736
841
SAMPLE
diameter per linear foot installed.
$
39,421
$
591,320
4,583
SCUM
$
346,317
$
5,194,754
14,356
SLUDGE
$
9,324
$
466,202
4,665
STEAM
$
84,494
$
4,224,717
23,657
WATER
$
4,317
$
215,829
1,407
OTHER
$
2,400,000
s17e,000,000
27e,000
Totals
3
Condition Assessments
-Determine the likelihood of failure and /or the
remaining life of the asset. I __ I
-Completed Assessments:
-Concrete
-Asphalt Paving
-Protective .Coatings
-Transformers
-Buildings re Seismic
-Presence of Hazardous Materials
-Critical Piping (Aeration)
-Elevators
-Electrical Switchgear
flr.r/W IYr1: ai!'Nei p.rMe.MY. Nr,hbr FYl errl
t,.� rrgr YgNrre,�e�F,Yr
rr,rrnrru.aF++s re»a�.
wr a.a
M�elsaYFr�,rsY.F SbrreY FrY. rr�rM1�Mr A� rrr.T
Mrw�.FFbrFew �,Frr,FM.r1��M�Mi Mle
Photo 13 Bey 1- Detect of Exposed
Aggregate Above Water lbw (Typi el)
i' 0'D=
J
Condition Assessment Results
Condition Assessment
Consultant
Year
Result
Cathodic Protection
JDH
2012
DP 5987, TP, CS & PS Cathodic Protection Survey
Electrical Switchgear
CDM
2011
OP 7292, Switchgear Refurbishment Phase 2
Outfall
contractor
2011
DP 7290, Outfall Improvements Phase 6
Protective Coatings
KTA -Tator
2010
DP 7247, TP Protective Coatings Phase 4; pTP16, Coating
Renovation; also included in other projects
Seismic— HOB
CPS
2009
DP 8226,Sesimic Improvements for HOB
Seismic— P &B
CPS
2009
DP 7291, Seismic Upgrades for Pump Blower Building
Asphalt Pavement
Fugro West
2009
pTP29, Pavement Renovations
ArcFlash Study
Protective Relay
Engineering
2009
Adjusted relay settings, procured additional PPE, signage,
and additional safety equipment
Concrete Structures
V&A Consulting
Engineers
2009
DP 7285, Primary Treatment Renovations; also included in
pTP30, Concrete Renovations
L;
Target Level of Service
Level of Service (LOS):
- full regulatory
compliance
• 14th Platinum Award
from NACWA for no
permit violations
- Safety
• 2011 Safe Plant of
the Year from CWEA
- Reliability &
Performance
AI Central [Doha CosW Sanhwy Dlshkt
Qua MISSION
To poi �publlc health and the
d6v tl iff ewa[u
OUR VtslDnr
ViEff7, Be a high pafmmanee organnoon that
proNaes exaTtional astomer service
n ��� at
"" OUR VALUES
we wig achieve as goals by valuing
• Eachoft
4 had" "ud`�uk"'''"""'"'°"
Determine Risk & Prioritize Projects
Assets
Likelihood of Failure
Consegpence of Failure
-Condition Assessment
-Age
-Redundancy
-Importance to operation of plant
-Capacity
-Meeting District Mission
-Efficiency
-Safety
-Spare Parts/ Obsolete
-Excessive maintenance
Business Risk Exposure (BRE)
Likelihood of Failure x
Consequence of Failure
Prioritize & Scope Proiects
Determine Projects & Group Appropriately
(e.g by system, process, type)
Incorporate - in 10 yr CIP] D
— �i
Determine Business Risk
Exposure (BRE)
BRE = COF x LOF
• COF is the consequence of failure.
- set for all assets in Mainsaver
- 10 high to 1 low
• LOF is the likelihood of failure and is based on
condition (if available), otherwise install date and
service life.
- 5 = F = very poor, imminent failure
- 1= A = excellent, new
Sample of Priority by Asset
Assetno
Description
BRE
11001, 11002
Influent Gate 1 & 2
50
87159, 87160
Sub 82 Normal & Emergency Feeder Switches
50
21300
Grit Structure
40
22201,2,3,4
Long Flight Collectors (in PSTs)
40
22105
Pri Sludge Pump 1
40
22121,2,4,5,6,45
Grit Pumps 1 -7
40
22400, 22401
MCC 22 131, 132
39
52102, 52150
Pri Effluent Pump 2, 3
35
52190
FE Pump 3
35
52000
P &B Building
28
System Priority by Ave BRE (initial)
CostCenter
Description
Reinvestment
($ /yr)
Ave BRE
Replacement
($)
22400
TUNNELS
123,167
22
9,131,605
21300
STEAM GENERATION
147,759
21
4,272,420
21600
SERVICE AIR
37,686
18
1,127,300
21500
FUEL SYSTEM
153,485
17
5,465,474
30400
CONCORD NORTH
METERING PS
6,388
17
97,500
15180
CAKE PUMPS
35,079
16
957,945
12000
SECONDARY
TREATMENT
2,727,986
16
176,226,442
15190
CENTRIFUGE
441,059
15
11,686,320
21200
POWER DISTRIBUTION
726,585
15
30,312,526
21700
WATERSYSTEMS
1,236,153
14
83,892,064
s
0
0 &M Strategies
Standard Operating Procedures
Operator Training Program
Skilled staff: •a„
— Operators 8hatdng Down a Funxa
— Mechanics
— Machinists
— Electricians;wa
aY1��q
— Instrument Techs
— Control Systems
ar Fabr a4ca a'MbWaq [aa aawabanaau WUaan.�ru
b waab
me wae+e a fie pba'aaa e n wean a eamQ
A—,* alto fw I.. ---.&
TMe a/e MO •WO b wti9 Gw� s /u1YK ll4OepIM i4p bt pKa
Abp• an a1 fa} a'�0 Rid
b t0
wam� b Gob rvroce� tai i
7
O&M Strategies
• Routine Preventative Maintenance
— mech, elec, & inst assets
— fixed intervals, run time, or decreased performance
• Predictive Maintenance
— Oil analysis
— Vibration
— thermography
• Adequate Spares
• Innovation, e.g.:
— Improved coatings to minimize wear
— Heat tempering to increase strength
Key Performance Indicators
• Minimal equipment out -of- service
• Negligible breakdowns
• Majority of work is scheduled (over 78 %)
versus unscheduled
• Hours are tracked per craft for backlog,
overtime, scheduled /unscheduled, call -
outs
• Work orders are tracked for the number
entered, completed, and open on critical
equipment A&
l
Recommended Breakdown for
future CIP
Rehab & Replacement Descriptions
Annual R &R Amount
Structures* — rehab & replacement
$5,100,000
Equipment — replacement
$8,800,000
Piping — replacement
$2,400,000
Equipment & Piping — protective coating rehab
$450,000
Subtotal
$14.31VI
Replacement Cost of Treatment Plant (PW)
$722M
Average Reinvestment Rate Per Year
2%
x $90
c
0
$60
$70
$60
$50
540
$30
$20
$10
S-
2013 2023 2033 2043 2053 2063
Yeor
*Average R &R from 1990 to present was $9M/yr since little
structure rehab & replacement has been required yet.
Based on Physical Mortality
Rehabilitation and Replacement
not regulatory drivers
2073 2063 2093 2103 2113
I
Long Term Funding
$35
■ CF . n�-val azd mm�.sn, ar±
S30
$25
¢ $20
O
$15
$10
$5
S-
F1...I Y—
To be determined by Management and the Board
Future Direction of TP Asset
Management
• Additional condition assessments
• Field inventory of piping w /TP GDI
• Evaluate CMMS /EAM software
• Confirm replacement $ and consequence of
failure rankings with POD & Engr.
• Determine how to report information to fulfill
management needs.
• Input from Board Members?
WC
Collection System Asset
S_
Capital Projects Committee Meeting
February 14, 2013
Collection System
Asset Management Program
Inventory the
collection
system
(GDI) Check
Condition -�
(CCTV) Capital Improvement
Plan: determine what
needs rehab /replacement
Construction, Rehab
Replacement
31-
1
Inventory of Collection System
• GDI
- As -built Drawings
- Overflow Locations
- Maintenance Records
- Hydraulic Capacity
- Permits-(laterals)
_ J
District -Wide CCTV Program
• Started in 2002
• Phase 1 - Inspect entire Collection System
(completed)
- Over 5,000 points
- 1,500 to 5,000 points -
- Less then 1,500 points
• Phase 2 - Re- inspection of pipes with less
then 1,500 points (1,450,000 feet, 18 %)
2
CCTV Program for Condition
Assessment
r
CCTV Classification Table
r m m ��
• M 1.. ��rr
• r . Yw
w `r�wrl�w M r�
3
Pipe Evaluation Flow Chart
Renovation Program Planning
• CCTV results - over 5,000 points
• Pipes Maintenance
- 6 months or less
- type of cleaning (hand rodding)
- group run
• Overflows /stoppages
• Capacity Issues - CSMP
• CSO Folders
• City's Paving Program
• Location - creek crossing, easement, street
• Social Impact - repair adjacent pipe segments
Goa ,
5
Contra CoMr Costa Sanitary District
FINAL REPORT
C`ollectiou Systeut Master Platt Update
R MC r..onrirr$ebrma.(w. Y
N'orn..J rlKr H.wr MAY 70I0
CIP & Long -Term Funding
• The industry- accepted replacement is 1% of the
collection system per year.
• Through CCTV we have identified the problems,
and target those for rehab /replacement.
• CCCSD replaces approximately 30,000 LF per
year and has targeted the worst pipes.
• CCCSD has significantly decreased the number
of overflows.
Running 12- Months Overflows Totals
Pumping Stations
M,M+Y LA_ raves
4 v
rr
B
m —
n r
Iw`q aai.
II
Mkt b
121
1
12 -Month Total at Month -End
Pumping Stations
M,M+Y LA_ raves
4 v
rr
B
m —
n r
Iw`q aai.
II
Major PS Renovation Projects
• San Ramon
• Lower Orinda
• Moraga
• Orinda Crossroads
• Martinez
• Sleepy Hollow
• Concord Industrial
• Acacia
• • • (41 ATA
- 3011 Update
tl'
Map of
°i� 8erviro
Aroa
eeeao w.ora Udi—
�.�.�. •tip..
Major PS Equipment Inventory
Operations and Reliability
.ucu vuwla sr.liosa
n•.o o., a.ru wm
nmraio�s
Irnr lu•
MIrY�Mwv NM•Y • si �iwMM�IYrla�l�rn� M
herll.�r IYYY�nw IY reYrn.�iw.•YYYIYr�wOwe�rr'
IT.www+s•IV ' i
tl111C
• YM Y�.rY.ry IM w rr �..4Y nw.Y u... � wwr
Or�i�rwY�e.Ywwa^r.w�H � �a�iw Y. MI�MY
ICY Owr Mw..Ylw
ra...rw.Yr, wm.
^�fMW rruw��•Mww iw.w� F�nr•.wwp.
wu wrt•�Owew�r�
br... r r rY� n vlw w rYw • �.a.w
4YIm (Ky
�rYr .e•.s�• Y
��'q �w rte•
rre
Mirelrwa.w
1^i.��mmp.w
•auYry.rw
~sl••ar •
_ ww www.r
�'I rr•y�nr MI. a.r.wr
�N� /wry
I�•w•p1ee�•wYgYruYMTM t+se�w•vswtnrM
wwrYpwtip�ww�irrw •�n�� wesw�w
qM lI. S.MA eY�m Yn nsa
bS6mlJtatC
•.WIT•+eYw�YpmYI Wipq p�nn•eiw/r�rr
�mMP�q� n��rnr•sirrown. -PIr
w+M.w �w•�W �NYn •hY.wurttrPrunW rw
aP��•o>/rbnoiesrw.aryw�•.arnu� r1Y0wm•
INPI+..rr•.V/n�wa�r
Po si. � eY•n t,+r. w � iryuewwwa •r�
I
Pumping Station Future
Projects
Mir Yr4Y ub �YwwYV fw Wn Nbsw.Yrrww M]
r-�b/ wb • ir]bY � ] YI]OY OYY
• Ytl - ewr]e� 4w. VY M W. �Irli r.N sN w
tiPYIYYbNnitlY ]Y+PO
rebus V9C. Lrtnhrw -t•
M]YYbiwI Yl]1-w]nYtllb YYffrtlYnYUbNYtlN ]M4]
b� OM1+b Ftl]tl M nv] b 4]r vnYtltl N a (lYk]] Mb1 Ya4N
ntl m]r]Yb.tltlr.. -utlw] rY...., ]Y6].YwOM]. o.m
wNr. u�]c] W e.�we- b..rvtl.o...Ytl4.]wrr..Ya.
iRb]� W4M]Y tlbr]Y1ry hY.�b 4]pwrY YltlryeY Y4tlryM
tlM FarldnYrnm M�bi1YY Ytltlw,w]tl
'll]mrnbtlY YbwbMR�je' Gpr]
• NYNe]yprnw orWyCtlM byma-Y�bptlwbprbm
btltivtlbM+- 4tl�]M].WMIwr ]�1] MtlCVV!
Yb YYbtltlMnlY�nmeUr]CSNVW bYY bYgw
YrYY�tlrsw.']svNm-
mrmbrWYUr YYwhv
PWY Ywr�wen. W SYiYtln MO+MN]Y+uYT
WsrM paa<4brrYprYwWMwibsgY]bwbpnr]tlM
OwvN Nn]IMYMtl Ywll]Y. Yb]hN]] tlQ`N W M1
YWYtlIW b]b]]pp]YYtltlnW l4per- Nw.
bb]wrtlYwY
Ywntl n Y- MpYYibYRGN MPaeYW b ]•ts0 ] Pb]r
_wa tl YMtl+ b�wtlrY tl rwrtl YY V � Y b+wr
• �]h]N h IDI1CyYlYpwvw]Nh.]bM mNKWtl
Mtl] 6m Name YnYnx la -r6M], l�tlYw IwtlY W ]w,bl.
w��uvu— f'.Ywur. t
Force Mains
• Condition Assessment Study
• Redundancies
- 2 -nd Force Main
- Emergency Bypass Features
- Inspection ports (Pig Launchers)
Corrosion Protection Monitoring
10
FORCE MAIN ASSESSMENT STUDY
DMTR1CT PROJECT sup
MY 0& 2010
tarter E,�MapE
ti�E wl�d.!
Ea CMamba
ow" Cella Ora lYel Dr»tt
Force Main Inventory
r�,�
oa2.
� r:ea
2 .omi• m+ • r
- ;51
+apg0
r•.rw L�u4 !•T•U• 01rM11• �m • ♦
apoll
ry,H •m .r. ro-J ♦
Y.y
a+a•4 !ry rc! rvu f
u�lv Dla•a � + TL¢•
w�
w�i.+.e�wr�w� ..r�r•.ysrr�..�.rwwn.nrnr�r.
11
Assessment Technologies
Pore /Aar YWa Ted-b"
.aN42010
P.ge{
Taela l: of DweWm Fan Wb 7
D
.rr.rm d
dti
�� a
ao.r.a.N..wY.�wr� .Mr r
rrrrrrrarrnsa a
awa
WNI w
wryo� r� rdr ~ i
inn- �NwwM�rr �
�w.�w.r
�rrssa rr>,
blotl Tlrnq.re N
Nprrrtlyrrrrtln arrrmYw w.a4 d
dwrf{r�
MwCwwrrdywrgrYYYlydbe b
bb+I..Y+Ir bB.w Yry w
wrnbNwrmp
ywY.Yrlbrrbadetlp// 1
1y.Npr+.rr.r41'
err r
yrrl �r..�.rrraw.byrlsi a
a..y.r.arrrr..w. e
ryr.r.
o.rb.aryrotlY w
row I
Iwbbtlyb.YSYNwswb.bmotlwr r
r�r �.wrbywY. d
dYrra
FYYPP �b.wrYy � bebW
eP.arwr,..r I
Iw brrw wwrr rr�r F
FrrrrirNlYrrr.AY I
IpolWrwr
euls Mw d
drrrrYtlr•M.rurr�rrdbpm b
b��IWrr/iwb r
rrsyrbuwiY
N O�rr� wiwi r r d d r Fe. rr
YgrwvFL l.rq N
NgNbwrdarr �tlbes• F
FYrYY ro.Y�Y+r.NYrr1� r
rb.dwYbrr
Mmn a
aw.rwwo.e.rr flsrrq.bY6�A .
..r�raN- e
ebr.
awrn.Nr rcM.. •
•wr. �r+b r..Ner�ro.Y.r..�oY. w
wr.�.y:rwi.rr�r r
rr�r .wr
Force Mains Assessment Priorities
Farce amt W.P fte T d..bpb
JW {, 2010
P .;a
.Y .W rrVVrrrrrt wrrNY Wrr GtlrYm
br ®wo>r Lrnye Rrrwtl.
Crrr{ Y N` N awlaYGy.lrvrtlq 1 %1 tlebrMMb Yrrb�r. Y�.rNabweYn
wswm reYnaNimr ararr� r a.. .rcw.r.0 aai.ebrr.a Y.ao
lm
Clye. N N N IimrOryl�waCgy aw 11E! reywOrw. &bwbrYwrrew.wrrrre
H¢OrwtlsrnrW dmir.Y6
aver N M N Iw Qr CyYlsn a0] tle6.rr�Yb.rlwar bbvYm.gviby.
Pr. Cwd. rIm b eYwY b M arr P�Crs RrrrY
wyO w Noon �1
YYey N. - Y Y .arN byt.rti tw �– 'rwrrrrY Vrr yr bYerq rr•reyr
YfYr.tawawoq e�wblYbrNN rrrr erNr.rra�b.. Y.rR Nye
dltirrYOanrFrdwr6i
Yr1Mr Y v Y dr wrNertrrwaY.a..
mYwntl FrNlt.aNrbr NW OrwrYrrrr a
fr kws� Y N N Paaru Glrs��U�lJ. 11iCi
6y.1 W.Ortaw
12
12
SEISMIC IMPROVEMENTS TO
DISTRICT BUILDINGS
• Not Recommended • Future -Plant Facilities
- Annex
- PBB
• Completed
- POB
- 4737 Imhoff Place
- SCB /Furnace
- HHWCF
- MRC
- Standby Power
- Lab
• In Progress
- Warehouse
- H0B
SEISMIC IMPROVEMENTS TO
DISTRICT BUILDINGS
• May need work
- Filter Plant
- UV inlet Gates
- Headworks (ducts, elec,
pipes)
- Headworks Grit Frames
• Future Work -Non Martinez
- CSO Vehicle Shop
- Martinez PS
• Equipment Anchoring
— Lower Orinda PS
• Equipment & Building
Anchoring, Bracing
- Crossroads PS
• Equipment Anchoring, East
Wall
— Moraga PS
• Equipment Anchoring, Bracing
13
Other Building Analyzes
• Treatment Plant Asbestos Survey
- Not comprehensive, mostly in tunnels
• Treatment Plant Lead Paint Survey
- Not comprehensive, project specific
• TP Roofs
- All major buildings have been done. Only
building remaining is SCB
• HVAC
- POD Maintenance report
t J ►
14
Fleet Asset Management
Don Rhoads
February 14, 2013
Central Contra Costa Sanitary Dtsb t
Mechanical Rodder
• 15 -year or '
150,000 -mile
l+
scheduled
replacement. -
• Hours based
on 34 miles per
hour.
r
Hydro Vac
- 15 -year or
150,000 -mile
scheduled1 I
replacement.
- Hours based -
on 34 miles per
hour.
Construction Crew Truck
(War Wagon)
- 12 -year or
150,000 -mile
scheduled
replacement.
• Hours based J'
on 34 miles er �" v
P _
hour.
Full -size Pickup Truck
- 10 -year or
100,000 -mile
scheduled
replacement.
Hybrid Sedan
1 0-year or
00,000-mile
scheduled
V
replacement. ;r
QUESTIONS?
Key Projects in the 2013 -14 and
2014 -15 Capital Improvement
Program
Capital Projects Committee Meeting
February 14, 2013
Central Contra Costa Sanitary DbWct
Collection System Prioritization
Collection System Asset
Management Plan
Identify and prioritize projects based
on:
— CCTV results
— Pipes Maintenance History
— Overflows /stoppages
— Capacity Issues — CSMP
— CSO Folders
— City's Paving Program
— Other agencies
— Location — creek crossing,
easement, street
— Social Impact
Coordinate and agree to
prioritization with all involved groups
(Planning, CSOD, Capital Projects)
7
t
Alf.
1
Treatment Plant Prioritization
• Continue Developing TP Asset Management Plan
— Prioritizing using a simplified, practical approach
— Prioritization occurs on several levels
Information gathered form several sources:
— Asset Management Data
— Condition assessments
— Maintenance input (routine, preventive)
— Operational input
— Safety
— Regulatory
— Long term planning
— Financial
• Identify critical projects
— Schedule projects based on: Risk of failure, regulatory drivers, safety,
reliability, performance, location, manpower, budget, etc.
— Coordinate and agree to prioritization with all involved groups (Plant
Operations, Plant Maintenance, Regulatory, Planning, Safety, Capital
Projects)
Proposed Ten -Year
Capital Improvement Program
0�
Proposed FY 13 -14 & FY 14 -15 Capital Improvement
Budget
CIB Program /Project
FY 2013 -14
Total Cost
FY 2014 -15
Total Cost
Treatment Plant Baseline
$ 8.7 million
$ 10.0 million
Collection System Baseline
$14.9 million
$13.6 million
General Improvements Baseline
$ 2.3 million
$ 1.5 million
HOB Seismic Improvements
$ 1.8 million *
$ 400,000
Recycled Water Baseline
$ 0.4 million
$ 0.6 million
Concord Landscape Irrigation
$ 1.5 million
$ 150,000
Total Baseline
$ 26.3 million
$25.7 million
Total Baseline + Concord REW
$29.6 million
$25.7 million
* One time seismic retrofits of HOB
FY 2013 -14 TREATMENT PLANT PROGRAM
CATEGORY
PROJECT
ANNUAL
EXPENSE
Reg. Compliance
Treatment Plant
Planning /renovations
$ 605,000
One Time
Renovation
Primary Treatment Renovation
$5,400,000
Pump & Blower Building Seismic
$ 850,000
Cogeneration Renovation
$ 400,000
Recurring
Renovation
Piping Renovation Phase 8
$ 100,000
Asset Management
$ 150,000
All Other
$1,209,000
Total Baseline
$8,714,000
FY 2014 -15 TREATMENT PLANT PROGRAM
CATEGORY
PROJECT
ANNUAL
EXPENSE
Reg. Compliance
Treatment Plant
Planning /renovations
$ 480,000
One Time
Renovation
Primary Treatment Renovation —
2nd year construction
$ 3,700,000
Pump & Blower Building Seismic
$ 2,200,000
Furnace Burner
$ 800,000
Aeration System Renovation
$ 800,000
Recurring
Renovation
Piping Renovation Phase 8
$ 150,000
Asset Management
$ 150,000
All Other
$ 1,766,000
Total Baseline
$ 10,046,000
NPDES Permit Adopted April 1, 2012
• Requires participation in collaborative studies to evaluate
the role of ammonia and ammonium in inhibiting primary
productivity (phyto and zoo plankton) in Suisun Bay.
Final report due 11 -1 -2014.
• Requires development of facilities plan to evaluate
alternative treatment technologies to remove ammonia and
site characterization for contaminated site.
Final report due 2 -28 -2014.
Permit "relook ...... April 1, 2015..... reassess the
appropriateness of the total ammonia load limit.
2
$10.5 M Primary Sedimentation Tank
Renovations Incorporates Condition
Assessment Findings and Improves Efficiency
• Proposed Renovations
— Replace Scum Collection System
— Replace Chain Drives
— Rehabilitate Concrete
— Replace water and air
supply piping
— Replace Scum Skimmers and Thickener
— Construct New Grit Handling Facilities
— Upgrade /Renovate Electrical Conduits /Equipment
Scum Spray System Requires Renovation to
Improve Performance
5
Grit Handling Facilities are Odorous and
Reaching End of Useful Life
Cogeneration Upgrades
• Repaired existing cogeneration unit
• Evaluated options
for upgrading
• Concluded that the
existing cogeneration
unit should be maintained until plant
energy demands increase significantly
(i.e. nitrification)
r�
Cogeneration Upgrades
• Required cogeneration unit upgrades for
five years maintenance contract with Solar
Turbines
— upgrade to electronic fuel valves
—new controls
—new fuel manifold /injectors for natural gas
— other
• Proceeding with recommended
improvements
Piping Renovation
Ongoing program to identify and replace
deteriorated piping
and equipment
throughout the
treatment plant.
Pump and Blower Building Houses Critical Plant
Equipment
C`1P
,®„ 0.:20
FY 2013 -14 COLLECTION SYSTEM PROGRAM
CATEGORY
PROJECT
ANNUAL EXPENSE
Renovation Program
North Orinda 5, Lafayette 8,
$ 10,601,000
Diablo 2, 2013 CIPP, TV
inspection and others
Compliance /Planning
Compliance /Planning
$ 520,000
Capacity /Renovations
Grayson Creek Trunk in
$ 1,600,000
Pleasant Hill
Pumping Stations
Moraga Pumping Station
$ 600,000
Grinder, Buchanan South
Removal
Contractual
Developer Services,
$ 1,181,000
Assessments/
Current CADs — Harper
Developer services
Lane, Willow Drive
All others
$ 417,000
Total
$ 14,919,000
FY 2014 -15 COLLECTION SYSTEM PROGRAM
CATEGORY
PROJECT
ANNUAL EXPENSE
Renovation program
North Orinda 6, Lafayette 9,
$ 10,151,000
Martinez 4, Walnut Creek 10,
TV inspection and others
Compliance /Planning
Planning
$ 270,000
Capacity /Renovations
Grayson Creek Trunk in
$ 1,000,000
Pleasant Hill
Pumping Stations
Flush Kleen Pumping Station
$ 300,000
Improvements, Fairview &
Maltby PS Improvements
Developer services
Developer Services
$ 800,000
Contractual
Current CADs — Harper
$ 500,000
Assessment Districts
Lane, Willow Drive
All others
$ 541,000
Total
$ 13,562,000
rti7•} r�
ov 2010
..,:,
Ongoing Program
Budgets -$I Milliori/Year
with Primary Focus in
,•
Orinda and .*�
Walnut Creek f�
"��:
9
t
I,.
�1.
Ploesant m
PNant HIII -
HIIYOroyson Crook � � .
Capacity Program
L.Nyatl ua uw
PNaunt HIII Road Road ^�r
(C bled In FY 2011112)
� ua
f .•- `rj... ".� /1* . a'O esw Wakwt Croak•
o. 1 3T /tea r Walnut 6Nd
M— . -
IP
M
L "7 Ban Ramon . .1y1 NM
uw=NV o.n�an�r onwo � � p�� ��. a.Mq tMn Ramon 6cMduN C \� \�
oe p
. NO GIDaO ar IMan k7av NM
u � �00g4
4 s1ULM Ni - .lYn
- %93014 1
10
Pumping Stations
• Completed major pumping stations
renovations /improvements
• Buchanan Pumping Station Abandonment
• Fairview /Maltby Pumping Stations
Improvements
• Moraga Pumping Station Grinder
11
FY 2013 -14 GENERAL IMPROVEMENTS PROGRAM
PROJECT
ANNUAL EXPENSE
Vehicles and Equipment
$
500,000
Information Technology
$
500,000
Seismic Improvements HOB
$
1,800,000
GDI Treatment Plant and
SMMS Replacement
$
600,000
All Other
$
691,000
Total
$
4,091,000
FY 2014 -15 GENERAL IMPROVEMENTS PROGRAM
PROJECT
ANNUAL EXPENSE
Vehicles and Equipment
$
500,000
Information Technology
$
500,000
GDI Treatment Plant and
SMMS Replacement
$
50,000
All Other
$
461,000
Total
$
1,511,000
12
HOB Seismic Retrofit
r
r
9ottom HeunM,.'pet
GDI & SMMS Replacement
Future Mb Nodol
........... . M
Cb�ery b*b�ao.
INnp.f bn/NA
.1
IN
FY 2013 -14 RECYCLED WATER PROGRAM
PROJECT
ANNUAL EXPENSE
Baseline - Pleasant Hill Zone 1,
Martinez Refineries and other
REW Planning
$ 356,000
Total Baseline
$ 356,000
Concord Landscape Irrigation
$1,500,000
Total
$1,856,000
FY 2014 -15 RECYCLED WATER PROGRAM
PROJECT
ANNUAL EXPENSE
Baseline - Pleasant Hill Zone 1,
$ 335,000
Martinez Refineries and other
REW Planning
$ 215,000
Total
$ 550,000
14
Concord Landscape Irrigation Project
Approx. 190
AFY
•••. •, Over 34 New
Customers
$4.4 million
total cost
m $1.2 million
Prop 84 Grant
' Bid in
_y
...• February 2013
15
Questions?
16