Loading...
HomeMy WebLinkAbout08.a. Accept the 2011 Sewer System Management Plan (SSMP Annual Audit Report)Central Contra Costa Sanitary District Q ' BOARD OF DIRECTORS V•Q.. POSITION PAPER Board Meeting Date: March 1, 2012 Subject: BOARD ACCEPTANCE OF 2011 SEWER SYSTEM MANAGEMENT PLAN ANNUAL AUDIT Submitted By: Initiating DeptJDiv.: David Hefflefinger, Assistant Engineer Collection System Operations Department/ Field Operations REVIEWED AND RECOMMENDED FOR BOARD ACTION: D. He efinger C. Swanson Ann Farrell Jam Kelly, Deputy General Gene anager Manager /Director of Engineering ISSUE: The Central Contra Costa Sanitary District's (District) annual audit of the Sewer System Management Plan (SSMP) has been prepared for submission to the California Regional Water Quality Control Board (RWQCB), San Francisco Bay Section. This annual audit is presented for the District Board of Directors' information and acceptance. RECOMMENDATION: Accept the 2011 SSMP Annual Audit. FINANCIAL IMPACTS: None ALTERNATIVES /CONSIDERATIONS: None BACKGROUND: The California State Water Resources Control Board Order No. 2006 -0003, "Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems," and the Regional Water Quality Control Board (RWQCB) required that an SSMP be prepared and that the SSMP contain 11 chapters. The SSMP was adopted by the District Board of Directors and as it now stands meets the requirements of the RWQCB. The RWQCB also required that an annual audit of the SSMP be prepared and submitted to the RWQCB by March 15 of the year following the year for which the analysis applies. The purpose of the audit is to evaluate the effectiveness of SSMP, analyze overflow and stoppage data for trends, and identify areas which may be lacking and need improvement. The audit for year 2011 is attached to this position paper. The audit is separate from the Annual Overflow Report previously provided to the RWQCB. Upon acceptance of this audit by the District Board of Directors, it will be submitted to the RWQCB by March 15, 2012. RECOMMENDED BOARD ACTION: Accept the 2011 SSMP Annual Audit. CSO /N: \Users \SJocovic \Ppaper \SSMP Audit 2011 ppaper.doc Central Contra Costa Sanitary District Sewer System Management Plan Annual Audit Report Date of audit February 23, 2012 Name of auditor David Hefflefinger, P.E. System Overview LF of gravity sewer mains 7.7 million (1,460 miles) LF of force mains 116,000 (22 miles) Total LF of all sewer line 7.9 million (1,500 miles) Number of pumping stations 17 Population served 322,000 (plus 134,000 sewage treatment only) Current monthly single family residential sewer rate - $28 /month ($341/yr) GOALS Are the goals stated in the SSMP still appropriate? eNO (circle one) Discussion: The goals guide Central Contra Costa Sanitary District ( CCCSD) to responsibly manage, operate, and maintain the sewer collection system. Additionally, the various CCCSD departments develop annual strategic goals which support the SSMP. II. ORGANIZATION REFERENCE MATERIAL ➢ Organization chart ➢ Phone list 2. Is the SSMP yp4Qdate with agency organization and staffing contact information? QS9 NO Discussion: Currently, the organization chart and phone list shown in the SSMP are updated annually after each audit, which means that some of the information will be incorrect some of the time. Every effort has been made to use job descriptions and job titles where possible instead of providing the actual name of the person assigned to a position to prevent the information from becoming outdated. CCCSD is looking into developing and maintaining the SSMP using single- source publishing to aid in keeping the information easily retrievable and up to date. Page 1 of 10 III. OVERFLOW EMERGENCY RESPONSE PLAN REFERENCE MATERIAL ➢ Data submitted to CIWQS ➢ Service call data Table 1. Annual SSO Statistics 3. Does the SSMP contain an up-to-date version of your agency's Overflow Emergency Response Plan . YES NO 4. Considering the information in Table 1, is the low Emergency Response Plan effective in handling SSOs? ES / O Discussion: The Overflow Emergency Response Plan is unchanged for the 2011 calendar year. CCCSD tracks the "average response time" (Table 1) on a monthly and yearly basis. The "average response time" is one indicator of the effectiveness of the Collection System Operations Staff's (CSOD) ability to respond to and handle a SSO. This year's average response time after normal working hours Page 2 of 10 2008 2009 2010 2011 2012 Number of dry- weather SSOs 86 63 43 37 Number of wet- weather SSOs 0 0 0 0 Total number of SSOs 86 63 43 37 Number of SSOs per 100 miles of sewer per year 5.7 4.3 2.9 2.5 Number of SSOs < 100 gallons 60 53 28 27 Number SSOs 100 to 999 gallons 19 9 13 9 Number of SSOs 1,000 to 9,999 gallons 7 1 1 1 Number of SSOs > 10,000 gallons 0 0 1 0 Total volume of SSOs (1000 gals) 27.2 6.1 21.6 10.3 Total volume recovered (1000 gals) 11.2 2.5 2.6 7.9 Net volume of SSOs (total minus recovered) (1000 gals) 16 3.6 19 2.4 SSOs caused by: Roots 64 50 34 22 Grease 7 2 4 3 Debris 13 8 5 9 Pipe failure 2 2 0 2 Pump station failure 0 0 0 0 Capacity - limited pipe segment (no debris) 0 0 0 0 Other 0 1 0 1 Number of locations with more than one SSO in the past year 2 0 0 0 Average response time (minutes) - during business hours 20 20 21 26 Average response time (minutes) - after business hours 37 37 36 39.5 3. Does the SSMP contain an up-to-date version of your agency's Overflow Emergency Response Plan . YES NO 4. Considering the information in Table 1, is the low Emergency Response Plan effective in handling SSOs? ES / O Discussion: The Overflow Emergency Response Plan is unchanged for the 2011 calendar year. CCCSD tracks the "average response time" (Table 1) on a monthly and yearly basis. The "average response time" is one indicator of the effectiveness of the Collection System Operations Staff's (CSOD) ability to respond to and handle a SSO. This year's average response time after normal working hours Page 2 of 10 was 39.5 minutes, slightly longer than previous years but within the CCCSD goal of 45 minutes. Another indicator of the District's effectiveness is the "net volume of SSOs" which is the total volume of SSO's minus the total volume recovered. For the year 2011, 7905 gallons were recovered through the efforts of the collection system crews. That is a recovery rate of 77 %. IV. FATS, OILS AND GREASE (FOG) CONTROL PLAN REFERENCE MATERIAL ➢ List or map of FOG sources in service ➢ List or map of hotspots ➢ Cleaning schedules ➢ Restaurant inspection reports or summaries ➢ Data submitted to CIWQS ➢ Service call data Table 2. FOG Control Statistics 5. Does the SSMP gpm4n up -to -date information about your agency's FOG control program t9 NO 6. Considering the information in Table 2, is the current FO gram effective in documenting and controlling FOG sources? YES NO Discussion: The District's Source Control section continued to implement the FOG control inspection program through 2011. Scheduled inspections, to cycle through the inventory of food service facilities, and reactive investigations, in response to problems downstream of food service facilities, were conducted. The Enforcement Response Plan was followed when violations of CCCSD's Source Control Ordinance were identified during these inspections. One formal enforcement action was taken against a food service facility in Pleasant Hill after a small overflow occurred due to grease plug of the District's line downstream of the restaurant which was the only grease source to the line segment that was blocked. Corrective actions were specified, and a fine and cost recovery for the CSOD staff time to respond to the overflow were collected, to resolve this enforcement action. Page 3 of 10 2008 2009 2010 2011 2012 Number of SSOs caused by FOG 7 2 4 3 FOG inspections for grease interceptor installation 15 19 10 23 FOG inspections for discharge compliance 638 454 606 525 Total number of FOG inspections completed 653 473 616 548 5. Does the SSMP gpm4n up -to -date information about your agency's FOG control program t9 NO 6. Considering the information in Table 2, is the current FO gram effective in documenting and controlling FOG sources? YES NO Discussion: The District's Source Control section continued to implement the FOG control inspection program through 2011. Scheduled inspections, to cycle through the inventory of food service facilities, and reactive investigations, in response to problems downstream of food service facilities, were conducted. The Enforcement Response Plan was followed when violations of CCCSD's Source Control Ordinance were identified during these inspections. One formal enforcement action was taken against a food service facility in Pleasant Hill after a small overflow occurred due to grease plug of the District's line downstream of the restaurant which was the only grease source to the line segment that was blocked. Corrective actions were specified, and a fine and cost recovery for the CSOD staff time to respond to the overflow were collected, to resolve this enforcement action. Page 3 of 10 V. LEGAL AUTHORITY 7. Does the contain up -to -date information about your agency's legal authority YES IO 8. Does your agejCy ve sufficient legal authority to control sewer use and maintenance? YES / NO Discussion: The CCCSD code that contains the legal authority is available online at www.municode.com /Library/. The text of each pertinent code that is referenced in the SSMP was reviewed and code 9.08.010 was found to have changed. The SSMP is undergoing an update this year and the revised code will be added. VI. MEASURES AND ACTIVITIES A. COLLECTION SYSTEM MAPS REFERENCE MATERIAL ➢ Summary of information included in mapping system 9. Does th P contain up -to -date information about your agency's maps? YES / O 10. Are your agency's c n system maps complete, up to date and sufficiently detailed YES NO Discussion: The CCCSD collection system maps are contained in a computerized geographic information system (GIS). The collection system maps are available to all employees through the CCCSD local network. Most field crews are provided paper map books, while a few have electronic maps loaded on special laptops. The CCCSD Engineering Support division performs map updates regularly in accordance with established procedures. If errors are found, map change requests are processed and the map updated. B. RESOURCES AND BUDGET REFERENCE MATERIAL ➢ Current Capital Improvement Plan (CIP) ➢ Current operating budget 11. Does the SSMP cont -to -date information about your agency's resources and budget? Qj O Page 4 of 10 12. Are your agency's resourceg-TaTft. budget sufficient to support effective sewer system management j. YES/ O 13. Do your agency's planning efforts support long -term goals 11& O Discussion: Each year the CCCSD Board of Trustees adopts budgets for staffing, operations and maintenance, equipment, and capital improvements. To meet budget requirements sewer rates were increased with residential sewer rates going from $311 to $341. The collection system department has hired 7 new employees in the calendar year 2011 in order to keep a fully operational maintenance staff. C. PRIORITIZED PREVENTATIVE MAINTENANCE REFERENCE MATERIAL ➢ Cleaning schedules ➢ List or map of hotspots ➢ Work orders ➢ Service call data ➢ Customer feedback Table 3. Annual Blockaae Statistics and Preventive Maintenance Activities 14. Does the SSMP contain up -to -date ipformVtion about your agency's preventive maintenance activities? QSJ1O 15. Considering the information in Tables 1 - 3, are your agency's preventive maintenance activities sp#4@iqnt and effective in reducing and preventing SSOs and blockages? YES/ O Page 5 of 10 2008 2009 2010 2011 2012 Blockages in the past year 130 80 20 25 Blockages due to: Roots 97 67 13 21 Grease 9 4 3 4 Debris 13 8 4 0 Other 11 1 0 0 Average response time (minutes) 35 24 26 26 Ratio of unplanned cleaning to planned cleaning (LF) .014 .16 .09 .21 Number of customer feedback surveys received in the last year 133 110 82 83 Average Rating in feedback surveys (4.0 max) 3.8 3.82 3.79 3.81 14. Does the SSMP contain up -to -date ipformVtion about your agency's preventive maintenance activities? QSJ1O 15. Considering the information in Tables 1 - 3, are your agency's preventive maintenance activities sp#4@iqnt and effective in reducing and preventing SSOs and blockages? YES/ O Page 5 of 10 Discussion: In 2011, the Capital Projects Division created the "Collection System Asset Management Plan" to aid in prioritizing the replacement and repair of existing sewer infrastructure. D. SCHEDULED INSPECTIONS AND CONDITION ASSESSMENT REFERENCE MATERIAL ➢ Inspection reports ➢ Infiltration and Inflow (1 /1) monitoring studies and reports ➢ Pipe and manhole condition data 16. Does the SSMP contain up -to -date inforpwAiqn about your agency's inspections and condition assessment . YES O 17. Are your agency's scheduled inspections and condition assessment em effective in locating, identifying and addressing deficiencies? Q!.!YO Discussion: CCCSD relies on an established maintenance schedule and CCTV sewer inspection to determine which pipe is in need of immediate cleaning. Experienced crew members review thousands of feet of video footage on a weekly basis. If a problem is seen in the video, a snapshot of the potential blockage is printed and attached to a work order. The sewer is then repaired or cleaned in a timely manner. This method is believed to have helped decrease the number of overflows as seen in the year to year trends by allowing us to optimize our cleaning efforts. E. CONTINGENCY EQUIPMENT AND REPLACEMENT INVENTORIES REFERENCE MATERIAL ➢ Funds spent on equipment and materials ➢ Equipment and parts inventory 18. Does the SSMP contain up4o<ate information about equipment and replacement inventories . YES O 19. Are contingency equipment and replacement parts sufficient and to emergencies and properly conduct regular maintenance? US, EO Discussion: CCCSD's replacement inventories and equipment budget for CSOD is reviewed yearly to keep the vehicle fleet fully operational and maintenance parts fully stocked. During the 2010 -2011 fiscal year, it was determined that the collection Page 6 of 10 system department needed two new vehicles. CCCSD is in the final stages of adding a rodder truck and a combo hydro /vacuum truck to the fleet. The finalized purchase will occur in 2012. F. TRAINING REFERENCE MATERIAL ➢ Employee training records 20. Does the SSMP contain up -to -date infqwAQ4ion about your agency's training expectations and programs? QD O 21. Do supervisors believe that their staff is sufficiently trained? 90 22. Are staf ied with the training opportunities and support offered to them? YES O Discussion: CCCSD maintains a training matrix for all employees. For CSOD, the Administrative Supervisor maintains the training records. For the 2011 calendar year, CSOD decided to add an overflow training video that will help crew members determine the rate of flow of sewage from a manhole. The training video is expected to be completed in the 2012 calendar year. CCCSD increased its Emergency Response Training for the pumping stations in 2011. Lower Orinda pumping station and Orinda Crossroads pumping station were part of a joint training exercise with the collections system and pumping station staff. G. OUTREACH TO PLUMBERS AND BUILDING CONTRACTORS REFERENCE MATERIAL ➢ Fliers /mailings ➢ Mailing lists 23. Does the SSMP contain up -to -date info rmati out your agency's outreach to plumbers and building contractors? Q9 O 24. Has your agency conducted or part' ' ted in any outreach activities to plumbers and building contractors? QD O Discussion: For 2011, the Outreach that was completed to Plumbers and Building Contractors consisted of communicating the latest version of the CCCSD Standard Specifications to the P &BC and collecting their comments /input. Upcoming outreach will include issues surrounding building demolition as well as overflow protection devices installations. Page 7 of 10 VII. DESIGN AND CONSTRUCTION STANDARDS REFERENCE MATERIAL ➢ Design and construction standards ➢ Ordinances 25. Does the SSMP contain up -to -date iyA7MVtion about your agency's design and construction standards . YES O 26. Are design and construction standards, as well as standards for inspection and testing of neyrart4 rehabilitated facilities, sufficiently comprehensive and up to date? Y9S, O Discussion: The last update for the design and construction standards occurred in the year 2011. Section 9.08.010 — Planning, design, and construction, of Chapter 9.08 — Public Sewers, of the CCCSD California Code of Laws has been revised. The revised version will be incorporated by reference when SSMP is updated this year. VIII. CAPACITY MANAGEMENT REFERENCE MATERIAL ➢ Capacity assessment reports ➢ CIP ➢ SSO data Table 4. SSOs Caused by Hydraulic Limitations 27. Does the SSMP conta' o -date information about your agency's capacity assessment Y O 28. Has your agency completed a capacity assessment entified and addressed any hydraulic deficiencies in the system YES O Discussion: The pumping station inventory was updated in 2011. The Collection System Master Plan was last updated in May 2010. The District intends to start the development of a new Pumping Station Master Plan in the near future. A facilities plan for the City of Martinez is being prepared. Page 8 of 10 2008 12009 12010 12011 tP12 Number of SSOs caused by capacity limitations 10 10 10 10 27. Does the SSMP conta' o -date information about your agency's capacity assessment Y O 28. Has your agency completed a capacity assessment entified and addressed any hydraulic deficiencies in the system YES O Discussion: The pumping station inventory was updated in 2011. The Collection System Master Plan was last updated in May 2010. The District intends to start the development of a new Pumping Station Master Plan in the near future. A facilities plan for the City of Martinez is being prepared. Page 8 of 10 IX. MONITORING, MEASUREMENT AND PROGRAM MODIFICATIONS 29. Does the SSMP contain up-tq,4&tk information about your agency's data collection and organization? Q!!> O 30. Is your agency's data collecti organization sufficient to evaluate the effectiveness of your SSMP . YES O Discussion: CCCSD prepares monthly reports which track overflows, partial blockages, sewer pipe footage cleaned, and pipe repaired. These reports are distributed to the collection system management staff, as well as to other departments for analysis and future decision making. In addition, CCCSD has a program to annually inspect at least 10% of the collection system pipes using CCTV. The inspection results allow staff to evaluate the sewers for repair or replacement and aid in identifying sewers for future renovation projects. The CCTV results also allow staff to assess the effectiveness of sewer cleaning efforts, and aid in determining the proper sewer maintenance frequency. X. SSMP AUDITS 31. Will this SSMP Audit be sub d to the Regional Water Board by March 15. YES O Discussion: SSMP audits are conducted on a yearly basis. Each audit becomes a supplement to the SSMP and is placed in Chapter 10 — SSMP Audits. XI. COMMUNICATION PROGRAM REFERENCE MATERIAL ➢ Mailings and mailing lists ➢ Website ➢ Other communication records such as newspaper ads, site postings or other outreach ➢ Customer feedback 32. Does the SSMP conlWa.up -to -date information about your agency's public outreach activities? Q.ES .J1 O 33. Does the SSMP contain up -to -date information about yo agency's communications with satellite and tributary agencies . YES O 34. Has your agency effectively communicated with the p nd other agencies about the SSMP and addressed feedback? ES O Page 9 of 10 Discussion: CCCSD communicates with the public in various ways. • Sewer Science is a weeklong wastewater treatment lab for high school students. The curriculum integrates chemistry, physics, and microbiology, while informing students about the District and the wastewater industry. In 2011, more than 1,300 students in six different high schools had Sewer Science as part of their curriculum. • CCCSD is a major sponsor of the Delta Discovery Program. This science program targets 5th grade students and takes them aboard the Marine Science Institute research vessel, the RV Brownlee, which was custom built to provide a safe and stable floating laboratory for students. On this three - and -a -half hour excursion on the Sacramento -San Joaquin Delta, students learn about the water in the Delta, its aquatic life, water conservation, the effects of pollution, and the work of wastewater agencies to prevent that pollution. A total of 2,204 students from the CCCSD service area took the voyage in 2011. • In 2011, the CCCSD website averaged more than 200 distinct visits every day for a total of 71,368 visits. • During 2011, CCCSD conducted a number of plant tours for nearly 200 people. • CCCSD's Speakers Bureau provides staff speakers at no cost to local organizations. Topics covered range from how the wastewater system works to pollution prevention. More than 600 people attended such presentations in the past year. • The Pipeline is an informational newsletter that is sent out three times a year to all CCCSD's customers to their homes and businesses to approximately 160,000 addresses. Page 10 of 10